Performance Specifications Overview

DIELECTRIC WITHSTANDING VOLTAGE:
Sea Level: 1,500 Volts AC (RMS)
At 70,000 ft:: 200 Volts AC (RMS)

INSULATION RESISTANCE:
5,000 meghoms at 25 C.

TEMPERATURE:
Operative at -65C to +200C.

FLUID COMPATIBILITY:
Method 1016 of MIL-STD-1344

CURRENT RATING:
Contact size 22-5 amps, size 20-7.5
Amps, size 16-13 amps, size 12-23 amps

MOISTURE RESISTANCE:
Method 1002, Type II of MIL-STD-1344

THERMAL SHOCK:
Per MIL- STD -1344 Test Condition A

CONTACT RETENTION:

Contact Size

Axial Load

22
20
16
12

12 lbs. min
20 lbs. min
25 lbs. min
30 lbs. min

GROMMET SEALING RANGE :
(MIL-T-81714, Table I)

Contact
Size

Max Wire O.D.

Min Wire
O.D.

22
20
16
12

.060
.083
.109
.142

.030
.040
.065
.097


OTHER TESTS PRERFORMED:
Vibration, Mechanical Shock, Altitude Immersion, Temperature Life, all per MIL-T-81714E


Download Complete